Load Cell Timbangan Digital MKCells MK-Di01P

https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEilrnKLYbpTZlpFZoXszMjHVOcfYBLohvkwEKHTV2F2vbOep3TLNCmPB7YigpPC6k_HwfwqiKYPiiAvYam3u8zeBWq_Zy_E5q5Yln3U2TC1P8E2ev8xqOgDLsc4mWZ_A7oB8q8wfOAEfoE/s72-c/Load+Cell+Timbangan+Digital+MKCells+MK-Di01P.png click to zoom
Ditambahkan 03.24
Kategori Digital Load Cell Produk
Harga Harga : Call @ MKCells MK-Di01P used for static truck scales, supporting 1~16 pcs P protocol digital load cells. Hardware Power:AC...
Share
Hubungi Kami
PESAN

DESKRIPSI Load Cell Timbangan Digital MKCells MK-Di01P

Harga : Call @

MKCells MK-Di01P used for static truck scales, supporting 1~16 pcs P protocol digital load cells.
Hardware
  1. Power:AC switch power 110V~220V/AC; no DC;
  2. LC interface:communication way:RS485; baud rate:19200bps;transmit distance:less than 50m
  3. Scoreboard interface:RS 232, current loop;rated baud rate is 600bps;
  4. Printing interface:EPSON LQ-300K+Ⅱ、KX-P1131、POS-58…etc are optional
  5. PC communication interface way:RS232,baud rate 600~19200bps optional

protocol characters
– Open protocol
– 8 bit data format,suitable for PC programming
– Baud rate is optional,O type max to 57600
– With function of checking LC overload record, full capacity, models…etc.
– Scalability, easy to add more function.
– Presetting all kinds of functions, like Gravity compensation and temperature compensation.
– Portability, easy to transplant to other platforms, such as CAN.

Character 1

  • Open protocol;
  • Support U type digital LC;
  • High performance 485 communication chip;
  • LC interface have surge protection measures;
  • support auto-networking, scale group.

Character 2
  • Support scale setting abnormal detecting
  • Auto-storage 1000 sets weighing record, no need cancel records.
  • Support PC communication interface self-detecting;
  • Support RS232 and RS485 PC interface, set by software.
  • Support key diagnostic;
  • Support address checking  during press angles.
Basic function 1
– Calibration and parameter setting operated separately;
– Score board interface;
– serial communication interface;
– standard parallel print interface, customizable print format;
– Comprehensive configuration EMC electromagnetic
compatibility protection measures;
– No encryption function between LC & indica-tor communication.
– No battery;
Basic function 2
– Auto & manual adjusting of angles.
– Overload record storage and printing function.
– Digital LC code self-detecting function.
– Fast detection of digital LC condition
– Two segment values, two ranges optional
– Nonlinear correction function;
– Weighing record storage/cancel/power off protection
– Storage 500 sets truck tare weight, 1000 sets weighing records.